- Bronze alloy or stainless steel bolt approved for direct burial in earth and concrete.
- Performs the functions of economy, standard duty, heavy duty, and extra heavy duty
- Able to withstand in excess of 350 in/lb of torque
- RUS listed

-
One Clamp Fits 1/2, 5/8 and 3/4 Rod Diameters. Catalog
NumberRod
SizeConductor
RangeSub &
Master PackWt.
per 100NAED
UPC
No.632591-SRC 1/2" 1/0 Str .- 10 Sol. 100 16 613286 SRC 5/8" 1/0 Str. - 10 Sol. 100 16 613286 SRC 3/4" 1/0 Str. - 10 Sol. 100 16 613286
Listed for galvanized and copper ground rods UL Listed for US and Canada This clamp accomodates all 1/2 and 5/8-inch rod diameters, and 3/4-inch copper-coated rods only. Will not fit 3/4-inch full-size galvanized, stainless steel or solid copper rods
-
- Bronze alloy or stainless steel hardware both UL listed approved for direct burial in earth and concrete
- Cast copper alloy body with hex head bolt provides simple trouble-free connection at low cost.

- †-The G-6 fits all 3/4-inch diameter rods regardless of actual or nominal diameter
- §- This item UL Listed for use on 1/2" and 5/8" copper-coated and galvanized rods, and #4 (1/2") rebar, buried in earth or concrete. Also RUS Listed
| Catalog Number |
Rod Size |
Conductor Range |
Sub & Master Pack |
Wt. per100 |
NAED UPC No.632591- |
| G-3 | 3/8" | 4 Str. - 10 Sol. | 100 / 800 | 6 | 70706-0 |
| G-4*(Use G-5) | 1/2" | 2 Str. - 10 Sol. | 100 / 800 | 9 | 70707-7 |
| G-5*§ | 5/8-1/2" | 2 Str. - 10 Sol. | 50 / 400 | 10 | 70708-4 |
| G-6*† | 3/4" | 2 Str. - 10 Sol. | 50 / 400 | 11 | 70709-1 |
*-These items UL and CSA Listed in US and Canada for direct burial in earth and concrete
-
- Bronze alloy or stainless steel hardware approved for direct burial in earth and concrete
- Cast copper alloy body with hex head bolt provides simple trouble-free connection at low cost on galvanized ground rods.

| Catalog Number |
Rod Size |
Conductor Range |
Sub & MasterPack |
Wt. per100 |
NAED UPC No.632591- |
| G3P | 3/8" | 4 Str. - 10 Sol. | 100 / 800 | 6 | 61135-0 |
| G4P* | 1/2" | 2 Str. - 10 Sol. | 100 / 800 | 9 | 61219-7 |
| G5P* | 5/8"-1/2" | 2 Str. - 10 Sol. | 50 / 400 | 10 | 61220-3 |
| G6P | 3/4" | 2 Str. - 10 Sol. | 50 / 400 | 11 | 61221-0 |
* RUS Listed and marked per RUS specification and traceability.
-
- Bronze alloy or stainless steel hardware both UL listed approved for direct burial i n earth and concrete
- Ground connection is secured by long bearing surface of clamp on ground wire.
- High-strength corrosion-resistant copper alloy. All Heavy Duty clamps UL Listed for direct burial in earth and concrete.

- -These items UL and CSA Listed except for JAB58HH and JAB34HH
- JAB58H Listed for US and Canada - 7/16 -14 threads
| Catalog Number |
Rod Size |
Conductor Range |
Sub & Master Pack |
Wt. per 100 |
NAED UPC No.632591- |
| JAB12H | 1/2" | 2 Str. - 10 Sol. | 100 / 800 | 12 | 70715-2 |
| JAB58H | 5/8" | 1/0 Str. - 8 Sol. | 50 / 400 | 13 | 70716-9 |
| JAB58HH* | 5/8" | 1/0 Str. - 8 Sol. | 50 / 400 | 14 | 61311-8 |
| JAB34H | 3/4" | 1/0 Str. - 8 Sol. | 25 / 250 | 15 | 70717-6 |
| JAB34HH | 3/4" | 3/0 Str. - 8 Sol. | 25/ 200 | 17 | 61495-5 |
| JAB1H | 1" | 4/0 Str. - 8 Sol. | 50 / 400 | 25 | 70718-3 |
*-HH represents “Heavy duty hex head design screw 1/2” – 13 threads
| Catalog Number |
Ground Rod Size |
Pieces/ Cartons |
WT/C | Ground Wire Size |
NAED UPC No.632591- |
| DGC-5844* | 5/8 (0.555 - 0.565) | 50 | 20 | 1 or 2 - #4 Sol. | 61329-3 |
| DGC-5866* | 5/8 (0.555 - 0.565) | 30 | 20 | 1 or 2 - #6 Sol. | 61330-9 |
- For use on all 5/8" diameter UL Listed copper-clad ground rods.
- Used to bond one or two, #4 or #6, solid copper conductors respectively.
- Produced from high-strength copper alloy, the same material as UL Listed "acorn" type ground rod clamps.
- May be used effectively for direct-burial applications.
- To install, the only required tool is a hammer. Compression forces maximize the “direct” surface-to-surface copper contact between conductor and ground rod electrode.
- A drive-head should be used during installation of the ground rod electrode into the soil, thus minimizing any possible mushrooming or deformation on the drive (or chamfer) end of the rod. This will improve ease of installation of the drive-on clamp.
- This design places the grounding conductor in “direct” contact with the ground rod, thereby eliminating multiple paths for the current to follow, which could contribute to increased resistance.
- Select the proper connector from the above chart.
- Drive the ground rod electrode to the proper depth per national or local code recommendations.
- Position connector and ground rod conductors as shown in middle illustration.
- Drive connector onto rod until top of connector is flush with top of ground rod as shown in adjacent illustration. Galvan suggests using a 20-ounce hammer.
-
To Install: